72651 Flow Through Heater 1kw/4k

$153.79
Out of stock
SKU
72651
Add to Wish List
Discontinued

72651 Flow Through Heater 1kw/4k
72651 Flow Through Heater 1kw/4k

Discontinued

Use 73994

The heater is a flow through type heater. The heater is powered and controlled by the control box. That is, power is supplied to the heater when the control thermostat determines the spa temperature is too low.

The heater is inserted in the discharge of the jet pump plumbing and is located under the control box. The heater is attached to the spa's plumbing using compression fittings at either end.

 Specifications:

  • 230 Volt AC, 4.0 kW, 16.6 Amps
  • 115 Volt AC, 1.0 kW, 8.0 amps
  1. Disconnect power to the spa.
  2. Drain the spa.
  3. Remove the equipment compartment door.
  4. Open the control box lid.
  5. Disconnect the pressure switch connection wires from the pressure switch.
  6. With two small wrenches of the same size, loosen the nuts that secure the heater connecting bars. Then disconnect the ground wire attached to the heater.

    WARNING: Always use both wrenches to loosen the heater connecting bar. The bottom nut is fused to the heater terminal to prevent the terminal from being twisted when the top nut is turned. If only one wrench is used to loosen the connecting bar, the torque applied to the heating element will be too great, and the heater will be permanently damaged.
     
  7. Remove the High Limit Sensor for the heater.
  8. Unscrew the heater inlet and outlet compression fittings.
  9. Rotate heater and pressure switch clear of the control box. Remove the pressure switch from the heater.

    CAUTION: There may still be some residual water in the plumbing.

    Installation:

    Reverse the removal procedure to install the heater in the equipment compartment (refer to the pressure switch installation procedure if necessary).

    NOTE: Be sure that the pressure switch and high limit sensor are positioned correctly before you slip the heater in place. After you are finished with the installation, switch the jet pump to high speed and check the compression fittings for leaks.

72651 Flow Through Heater 1kw/4k is for the following models: 

Make Model Date Range
Hot Spot Mallorca 2003-2005
Hot Spot Sorrento 2003-2005
Hot Spot Tobago 2003-2005
Hot Spot Trinidad 2003-2005
Caldera Palomar 2004-2005
Caldera Cumberland 2002-2005
Caldera Olympia 2002-2005
Caldera Cascade 2002-2003
Caldera Oasis 2002-2005
Specifications

 

Item Description Part #
1 GFCI 15AMP In-Line 125V 37870
2 Light Receptacle 71612
3 Control Box 72469
4 Thermostor Control 71578
5 Pressure Switch 71586
6 Heater Assy 72651
7 Split Nut Union 2" 33761
* Fuse 25A/300V SC Time Delay 71618
* Fuse 2A 250V 3AG Slo-Blo 34934
* Fuse 750 mA/250V 5 X 20MM Fast-Blo 0965201
* Tailpiece Heater 70905
* O-Ring Tail Piece 34447 

Item Description Part #
1a GFCI W/Cover For 115V System 20 AMP 70922
1b Cord GFCI For 115V System 20120
* Breaker GFCI Subpanel Box For 230V System 38661
2 Light Receptacle 71612
3 Control Box 72469
4 Thermostor Control 71578
5 Pressure Switch 71586
6 Heater Assy 72651
7 Split Nut Union 2" 33761
* Fuse 25A/300V SC Time Delay 71618
* Fuse 2A 250V 3AG Slo-Blo 34934
* Fuse 750 mA/250V 5 X 20MM Fast-Blo 0965201
* Tailpiece Heater 70905
* O-Ring Tail Piece 34447