This part is a replacement light cover control panel for select Hot Spring hot tubs. The light cover protects the control panel's light and its components.
Designed in white for a sleek appearance. Compatible with 1994 to 2010 Hot Spring Highlife spa models.
*Check specs section for full list of compatible models and years.
There are two locking features to the control panel, TEMPERATURE LOCK and SPA LOCK.
Spa Lock deactivates all functions of the control panel and is activated by pushing the LIGHT minus (-) and TEMP minus (-) at the same time and holding them down until the word SPA and the lock symbol are illuminated on the control panel display.
Temp Lock deactivates the temperature control function of the spa and is activated by pushing the LIGHT plus (+) and TEMP plus (+) at the same time and holding them down until the words SET TEMP and the lock symbol are illuminated on the control panel display.
Note: Unlock either system by reversing the corresponding process.
Indicator Lights
All spa models have an indicator light on the control panel. As well as being a power on indicator, the indicator light also serves as the signal light for the diagnostic feature incorporated in the Interlock/Timer circuit board. This light allows the homeowner to visually identify if a problem exists with the spa.
Power Indicator
Steady light indicates spa is working properly.
No light indicates a problem with the source power source to the spa.
Flashing light indicates an open interlock circuit.
Gently pull the control panel away from the spa only far enough to thread the panel back through the cutout and into the equipment compartment. Caution: The fiber optic cables (if applicable) can be damaged or become dislodged by excessive pulling on the control panel.
Access the IQ 2000 control box.
Disconnect and remove the control panel ribbon cable (if applicable).
Separate the control head from the control panel.
To reinstall the control panel, reverse steps 1 to 7.