The heater receptacle is located in the control box and provides power to the heater.
The heater receptacle will have power only when the control thermostat calls for heat and the flow switch (if equipped) is closed.
34835 Replacement Heater Receptacle 220 V is for the following models:
Make |
Model |
Date Range |
Hot Spot |
Square |
1995-1997 |
Specifications
Removal
|
- Disconnect power to the spa.
- Access the equipment compartment.
- Remove the control box.
- Locate the heater receptacle.
- Remove the Hot (black) wire from heater relay.
- Remove the Neutral (white) wire from heater relay.
- Disconnect the Ground (green) wire from the grounding lug inside the control box.
- Remove the receptacle by forcing it outward through the control box.
- To reinstall the heater receptacle, reverse steps 1 to 8.
|
|