31829 Circulation Cordset
Add to Wish List
Circulation Cordset
This is a power cord for the Silent Flo 5000 circulation pump. The cord comes in 48 inches and has a square plug.
On spas prior to 1999, the thermal cut-off automatically resets when the pump cools down. However, on all spas starting in 1999, the thermal cut-off will only reset when power is disconnected from the spa.
Specifications
Minimum flow for the circulation pump is 1 gallon in 30 seconds. (back to top)
Disconnect power to the spa.
Access the equipment compartment.
Unplug the circulation pump from the control box.
If the spa is filled with water, clamp the circulation pump inlet and outlet tubing with Hose Clamp Pliers.
Remove the bonding wire and base bracket screws.
Using Spring Clamp Pliers, slide the spring clamps located on the inlet and outlet fittings back onto the vinyl tubing.
Remove the
vinyl tubing from the pump inlet and outlet fittings.
Disconnect the electrical cord for the old pump. Take note of the electrical hookup.
CIRCULATION PUMP INSTALLATION
Install the original electrical cord onto the new pump.
Reverse steps 3 to 7 of the Circulation Pump Removal instructions.
Check for water leaks.
Reconnect power to the spa.
Perform a water flow test.
Check for any air in the
plumbing lines . If air does not clear, bleed off the air at the closest tubing clamp.
Reinstall the equipment compartment door