This part is a replacement power cord for select Hot Spring hot tubs. Made for the circulation pump Silentflo 5000 and E5.
Slide the flag terminals onto the spades inside the IQ2000 and the IQ2020 control boxes. Compatible with 1994 to current Hot Spring Highlife, Limelight, and Tiger River spa models.
*Check specs section for full list of compatible models and years.
Refer to the following instructions to install an electrical cord / ground on a no-cord SilentFlo 5000:
Remove the end cap of the new SilentFlo 5000 pump by removing the two slotted screws on the rear black panel.
Insert the stripped ends of the cord through the rubber gasket on the end cap.
Connect the ground wire (green) to grounding lug located on the body of the pump.
The other two wires should be installed into the terminal block. The pump is not affected by the polarity of the incoming power, so either wire can be installed in either terminal. NOTE:Insure that excess wire does not protrude from the rear of the terminal block. Excessive wire will cause direct shorts.
After the wires are secure, reinstall the end cap using the two slotted screws.
If an exterior grounding wire exists, you must attach the exterior grounding lug with single screw (provided in kit). Then attach exterior grounding wire to exterior grounding lug.